Search results for "efficiency [trigger]"
showing 10 items of 27 documents
Experimental validation of the BAC factor method for lighting systems
2017
In the last few years, many buildings have been equipped with Building Automation and Control (BAC) systems. BAC systems can be used to achieve a significant reduction of the electrical consumption and to have all the well acknowledged benefits from the daylight (e.g. occupant comfort, health, well-being and productivity). For this reason, Standard EN 15232 "Energy performance of buildings — Impact of Building Automation, Controls and Building Management" puts into evidence the importance of the presence of BAC and Technical Building Management (TBM) systems, suggests a classification of these systems, explains their main functionalities and presents a simplified method to estimate their im…
Control and design for efficiency improvement of permanent-magnet synchronous motor drives in household appliances
2011
This paper deals with some aspects of efficiency improvement of PMSMD (Permanent Magnet Synchronous Motor Drives). Particularly two aspects are focused: the control algorithm for the PMSMD, which allows to reduce the power losses of the electric drive without penalty on its dynamic performances and the optimization of an IPMSM (Interior Permanent Magnet Synchronous Motor) rotor configuration capable to increase the performances in terms of shaft torque production, limiting at the same time the rotor leakage flux. The loss minimization algorithm is here briefly analyzed, a test bed for experimental validation is presented and the data are analyzed. Experimental tests have been performed aimi…
Experimental investigation on high efficiency real-time control algorithms for IPMSMs
2014
This paper describes an experimental investigation on the power losses variations occurring in an Interior Permanent Magnet Synchronous Motor (IPMSM) with respect to the direct axis current component. Such investigation can be useful to determine a mathematical model accounting for copper, iron and mechanical friction losses, and for the arrangement of a speed control drive system equipped with a real-time power losses minimization algorithm. In particular, a test bench has been set up in order to carry out all measurements and the final power loss identification. The test bed is composed by a IPMSM drive with a field oriented control (FOC) strategy, a power analyzer, a dynamometric brake a…
DEA-like Models for the Efficiency Evaluation of Hierarchically Structured Units
2004
Abstract The knowledge of the internal structure of decision making units (DMUs) gives further insights with respect to the “black box” perspective when considering data envelopment analysis models. We present one-level and two-level hierarchical structures of the DMUs under evaluation. Each unit is composed of consecutive stages of parallel subunits all with constant returns to scale. In particular, the maximization of the relative efficiency of a DMU is studied. For the two-stage situation, different degrees of coordination among the subunits of the hierarchical levels are discussed. When some form of coordination has to be guaranteed, we introduce balancing constraints and we compare two…
Efficiency of Telematics Systems in Management of Operational Activities in Road Transport Enterprises
2020
Implemented in road transport enterprises (RTEs) on a large scale, telematics systems are dedicated both to the particular aspects of their operation and to the integrated fields of the total operational functioning of such entities. Hence, a research problem can be defined as the identification of their efficiency levels in the context of operational activities undertaken by RTEs (including more holistic effects, e.g., lowering fuel/energy consumption and negative environmental impacts). Current research studies refer to the efficiency of some particular modules, but there have not been any publications focused on describing the efficiency of telematics systems in a more integrated (holist…
A Multifunctional Public Lighting Infrastructure, Design and Experimental Test
2017
Nowadays, the installation of efficient lighting sources and Information and Communications Technologies can provide economic benefits, energy efficiency, and visual comfort requirements. More advantages can be derived if the public lighting infrastructure integrates a smart grid. This study presents an experimental multifunctional infrastructure for public lighting, installed in Palermo. The system is able to provide smart lighting functions (hotspot Wi-Fi, video-surveillances, car and pedestrian access control, car parking monitoring and support for environmental monitoring). A remote control and monitoring platform called “Centro Servizi” processes the information coming from…
L'éducation en Afrique sub-saharienne. Les indicateurs d'efficience et leur utilisation politique
2005
05047; National audience; Cet article examine l'idée selon laquelle les systèmes éducatifs africains ne souffriraient pas tant d'un manque de ressources que d'une mauvaise utilisation de celles-ci. Deux arguments soutiennent cette idée. Le premier relève d'une comparaison internationale de l'efficience fondée sur un indicateur -part des dépenses d'éducation dans le PIB / durée moyenne de scolarisation- défectueux. Le second rrelève de l'estimation des fonctions de production scolaire dont l'interprétation commune des résultats est incorrrecte. Cette double argumentation, discutable, dissuade une forte augmentation de l'aide et encourage l'expansion de systèmes dont la médiocrité, conforme à…
Life Cycle Assessment of a compact Desiccant Evaporative Cooling system: The case study of the “Freescoo”
2016
Abstract The paper aims at exploring the performances of a compact Desiccant Evaporative Cooling system called “Freescoo” (Free Solar Cooling) in comparison to standard conventional technologies. The Freescoo – that aims at applications in the residential sector and in small office buildings and includes a photovoltaic–thermal system – is analyzed, its monitored performance discussed and reported: under cooling conditions an Energy Efficiency Ratio of 12.8 is calculated, that reaches 50.7 if also photovoltaic generation is considered. To assess the performance of the proposed system a Life Cycle Assessment study was performed to investigate the system covering all its life, from the product…
Characterization of cooling loads in the wine industry and novel seasonal indicator for reliable assessment of energy saving through retrofit of chil…
2020
Abstract The food sector is a major consumer of energy and growing efforts are being made in the search for solutions that will guarantee the efficient and sustainable use of energy resources. Among the different sectors, wineries are attracting particular interest due to the continuous growth of the global market and production. Surveys conducted in the winemaking sector have highlighted the importance of performing accurate energy audits and have identified the installation of efficient refrigeration systems as a promising solution in a variety of cases. Unfortunately, the savings achievable by efficient cooling technologies are often estimated using simplified approaches which do not tak…
Hierarchizing Energy Saving Strategies in Wine Industry by Advanced Modelling of Chilling Units Operation
2019
Wineries are energy intensive industries and in order to make the production process more sustainable, solutions for an efficient use of energy should be implemented. Large surveys conducted in the wineries sector have highlighted the importance of performing accurate energy audits and have identified in the installation of efficient cooling/refrigeration systems the most promising solutions in a variety of cases. Unfortunately, the savings achieved by such energy efficient solutions is often calculated by highly simplified approaches, which do not take into consideration the actual operating conditions of the equipment (highly variable on a seasonal and daily basis). In this paper a system…